PMS plan, PMS report and PSUR written from your own data
We write your post-market surveillance plan, the PMS report for Class I devices and the periodic safety update report (PSUR) for Class IIa, IIb and III devices. We build the reports from your own complaint, sales and incident records and complete them with a search of the literature and of public information on similar devices. When a serious incident or a field safety corrective action comes up, we help you prepare the report. To start, send us the device list, your current PMS documents and the complaint records for the last period, or use our proposal form.
Who this is for
Manufacturers whose technical documentation has no PMS plan yet, or whose PMS report or PSUR is out of date.
Manufacturers of Class I and Class A devices, who write the PMS report under their own responsibility without a notified body reading it first.
Manufacturers of Class IIa, IIb and III devices who have to update the PSUR on a fixed cycle and want the writing done outside the company.
Manufacturers outside the EU who need the PMS documents in order and ready for their authorised representative or a competent authority.
What the Regulation requires
Post-market surveillance is part of the quality management system and is set up for each device:
"For each device, manufacturers shall plan, establish, document, implement, maintain and update a post-market surveillance system in a manner that is proportionate to the risk class and appropriate for the type of device. That system shall be an integral part of the manufacturer's quality management system referred to in Article 10(9)." (MDR Article 83(1))
The system rests on a PMS plan written to Section 1.1 of Annex III (Article 84). For Class I devices the output of the plan is a PMS report:
"Manufacturers of class I devices shall prepare a post-market surveillance report summarising the results and conclusions of the analyses of the post-market surveillance data gathered as a result of the post-market surveillance plan referred to in Article 84 together with a rationale and description of any preventive and corrective actions taken. The report shall be updated when necessary and made available to the competent authority upon request." (MDR Article 85)
For Class IIa, IIb and III devices the PSUR takes its place, and the update cycle depends on the class:
"Manufacturers of class IIb and class III devices shall update the PSUR at least annually. That PSUR shall, except in the case of custom-made devices, be part of the technical documentation as specified in Annexes II and III. Manufacturers of class IIa devices shall update the PSUR when necessary and at least every two years. That PSUR shall, except in the case of custom-made devices, be part of the technical documentation as specified in Annexes II and III." (MDR Article 86(1))
For IVDs the same structure is in the IVDR: a PMS report for Class A and B devices under Article 80 and a PSUR for Class C and D devices under Article 81. We explain the wider framework in our article on post-market surveillance under MDR and the PSUR in detail in our article on PSUR under Article 86.
What goes into the PMS plan
The plan follows Section 1.1 of Annex III. It states where the data comes from, how it is assessed and at which point action is taken:
Information on serious incidents and field safety corrective actions.
Records of non-serious incidents and data on undesirable side-effects.
Information for trend reporting under Article 88.
Relevant specialist or technical literature, databases and registers.
Feedback and complaints from users, distributors and importers.
Publicly available information about similar devices.
For each source the plan sets who supplies the data, how often and in what format, and how it feeds back into the risk management file, the clinical evaluation and the instructions for use. The plan is proportionate to the risk class and to the risk analysis in your technical documentation.
What goes into the PMS report and the PSUR
Both documents summarise the data gathered under the plan, with the rationale and description of every preventive and corrective action taken in the period. The PSUR also covers the three points listed in Article 86(1):
The conclusions of the benefit-risk determination.
The main findings of post-market clinical follow-up (PMCF). You supply the PMCF findings and we write them into the PSUR.
The volume of sales, an estimate of the size and other characteristics of the population using the device and, where practicable, the usage frequency.
We identify the device by its Basic UDI-DI in every report, so the report matches the device in your declaration of conformity and in EUDAMED. We check the device name, models and class in the report against your declaration of conformity.
Vigilance: serious incidents and FSCA
Serious incidents and field safety corrective actions (FSCA) are reported to the competent authorities under Article 87(1). The deadlines are short:
"Manufacturers shall report any serious incident as referred to in point (a) of paragraph 1 immediately after they have established the causal relationship between that incident and their device or that such causal relationship is reasonably possible and not later than 15 days after they become aware of the incident." (MDR Article 87(3))
In a serious public health threat the limit is 2 days (Article 87(4)); in the event of death or an unanticipated serious deterioration in a person's state of health it is 10 days (Article 87(5)). Where needed, an initial report can be followed by a complete one (Article 87(6)).
We do not take the vigilance decision for you. Whether an event is reportable and whether there is a causal link is the manufacturer's decision. We draft the report from the information you have, list what is missing, draft the field safety notice for an FSCA and support the submission. The deadlines and the reporting flow are explained in our article on serious incident reporting.
Where Medex is your authorised representative, two vigilance tasks are written into the mandate by Article 11(3): "(f) cooperate with the competent authorities on any preventive or corrective action taken to eliminate or, if that is not possible, mitigate the risks posed by devices;" and "(g) immediately inform the manufacturer about complaints and reports from healthcare professionals, patients and users about suspected incidents related to a device for which they have been designated;"
Serious incidents are reported on the European Commission's Manufacturer Incident Report (MIR) form. The Commission's page on post-market surveillance and vigilance reporting forms states: "New MIR form - mandatory as from 1st May 2026". We prepare the report on the current MIR 7.3.1 form and the field safety notice on the Commission's template.
Process
You send the device list with classes, the current PMS plan or earlier reports, and the risk analysis section of the technical documentation.
We read the existing documents against Articles 83 to 86 and Annex III and send you a list of missing sections and the data we need.
You send complaint, sales, incident, corrective action and, where available, PMCF records. We search the literature and public information on similar devices.
We write the PMS plan, the PMS report or the PSUR and send you the draft.
You review the draft. We work in your comments and send the final version ready for signature.
We update the document in the next period with the same structure: every year for Class IIb and III, when necessary and at least every two years for Class IIa.
What you receive
A PMS plan written to Section 1.1 of Annex III.
A PMS report for Class I devices and for Class A and B IVDs.
A PSUR for Class IIa, IIb and III devices and for Class C and D IVDs.
A summary of the literature and similar device search with its source list.
Data collection templates: complaint log, incident log, sales and usage tables.
When vigilance is needed, a draft serious incident or FSCA report and a draft field safety notice.
What we need from you
The device list: device name, models, risk class and Basic UDI-DI.
The current PMS plan and earlier PMS reports or PSURs, if any.
The risk management and clinical evaluation sections of the technical documentation.
Complaint and incident records and corrective and preventive action records for the period.
Sales figures and the countries where the device is sold.
The PMCF plan and PMCF report, if any.
The declaration of conformity, to cross-check names, models and class.
Out of scope
Notified body conformity assessment and certification.
Testing and laboratory work, including choosing a laboratory or arranging tests.
Interpreting or changing your technical specifications.
Finding importers or distributors.
We do not run PMCF studies or clinical investigations, and we do not decide on reportability or causality on the manufacturer's behalf.
Related services
FAQ
Does a Class I device need a PSUR?
No. Article 85 requires a PMS report for Class I devices. The PSUR under Article 86 applies to Class IIa, IIb and III devices.
How often is the PSUR updated?
At least annually for Class IIb and III devices, and when necessary and at least every two years for Class IIa devices (Article 86(1)).
Do I have to send the PMS report to the authority?
Article 85 requires the report to be updated when necessary and made available to the competent authority upon request. It has to be ready in the technical documentation.
We have no complaint records. Can the report still be written?
Yes. If there are no records, the report says so and the plan sets out how records will be kept from now on. Data that does not exist is not put into the report.
Do you submit serious incident reports for us?
We prepare the report and support the submission. The manufacturer decides whether the event is reportable and whether there is a causal link, and the report is submitted on the manufacturer's behalf.
Do you run PMCF studies?
No. You supply the PMCF findings and we write them into the PSUR. The PMS plan states whether a PMCF plan is needed.
Do you also write PMS documents for IVDs?
Yes, under Articles 80 and 81 of the IVDR: a PMS report for Class A and B devices and a PSUR for Class C and D devices.