EMDN and GMDN Code Assignment, EUDAMED and Türkiye

EMDN code checked against your DoC and EUDAMED rules, plus GMDN and ÜTS fields for Türkiye.

EMDN and GMDN codes checked against your declaration of conformity

We identify the EMDN code for each of your devices, check it against your EU declaration of conformity and certificates, and prepare it for EUDAMED device registration. For devices also sold in Türkiye, we check the GMDN code, the EMDN term and the specialty field required by ÜTS, the Turkish Product Tracking System. You receive one code table per device family, showing where each code came from and which rule it follows. To start, send your declaration of conformity, any notified body certificate and your device list through our proposal form.

Who this is for

  • Non-EU manufacturers registering devices in EUDAMED who need one consistent nomenclature code per device.

  • Manufacturers updating or reissuing an EU declaration of conformity and adding the EMDN code to it.

  • Manufacturers and importers placing devices on the Turkish market, where ÜTS checks the codes against the documents.

  • Companies preparing a bulk upload, where one wrong code repeats across every row of a device family.

Legal basis

The MDR requires a single, internationally recognised nomenclature for EUDAMED:

"To facilitate the functioning of the European database on medical devices (‘Eudamed’) as referred to in Article 33, the Commission shall ensure that an internationally recognised medical devices nomenclature is available free of charge to manufacturers and other natural or legal persons required by this Regulation to use that nomenclature." (MDR Article 26)

The nomenclature code is one of the core data elements that the manufacturer enters in the UDI database:

"The manufacturer shall provide to the UDI database the UDI-DI and all of the following information relating to the manufacturer and the device:" (MDR Annex VI, Part B)

"the medical device nomenclature code as provided for in Article 26," (MDR Annex VI, Part B, point 8)

The IVDR contains the same rule in Article 23 and lists the nomenclature code in point 8 of Part B of its Annex VI. The nomenclature made available under these articles is the European Medical Device Nomenclature (EMDN).

EMDN in EUDAMED and in your declaration

The EMDN code you enter in EUDAMED should be the same code that appears in your declaration of conformity and, where a notified body is involved, in your certificate. When the declaration is drafted by one person, the EUDAMED data by another and the Turkish registration by a third, the codes drift apart. We build one code table and use it as the single source for all three. For background on the nomenclature itself, see our article on the EMDN code; this page describes the service of assigning and checking the code for your devices.

The code sits next to the Basic UDI-DI in the device record. If you are still assigning Basic UDI-DIs, our article on the Basic UDI-DI explains how the two relate.

Türkiye: three code fields in ÜTS

Türkiye applies the MDR through its own Medical Device Regulation, and every device sold there is registered in ÜTS. The Turkish Medicines and Medical Devices Agency (TİTCK) sets the rules for the code fields in its ÜTS registration guideline, TCKKD-KLVZ-03, Article 27 for MDR devices and Article 30 for IVDR devices:

  • GMDN: mandatory. Each device has one GMDN code. If a GMDN code appears in the EU certificate or the declaration of conformity, that code is selected. If not, the code supplied by the manufacturer is used, or the code that best describes the device. GMDN Agency data is treated as the valid reference.

  • EMDN: if an EMDN code appears in the certificate or declaration, the most detailed code and terminal term related to it must be selected. If the documents carry no EMDN code, the field is optional until TİTCK decides otherwise. Each device has one EMDN code, and higher level codes are not accepted.

  • Specialty type (branş türü): mandatory. The option that describes the device exactly is selected, or the closest one when no exact option exists.

The guideline also requires the GMDN description to match the device: a single use device must not carry a reusable device's term, and sterile status must agree. Where a code is valid but missing from ÜTS, a request to add it is filed through the ÜTS request screen. We draft that request with the guideline article as its basis.

What we check

  • The EMDN and GMDN codes in the declaration of conformity and the certificate match each other and the codes to be entered in EUDAMED and ÜTS.

  • Where the declaration gives a higher level EMDN code, the most detailed terminal term under that code that fits the device is identified for ÜTS.

  • Single use and sterile status in the GMDN description agree with the label, the instructions for use and the device record.

  • Devices from the same family linked to different GMDN codes are kept apart in the Turkish application.

  • The specialty type in ÜTS fits the intended purpose.

We do not change the code in your documents

If your declaration states a code, that code is what goes into the registration. We do not replace it with our own interpretation. If we see a mismatch between the code and the device, we report it with the reason, and the correction is made in the manufacturer's document. A GMDN code we cannot verify is not filled in by guesswork.

Rejections we have seen in Türkiye

  • The declaration of conformity stated an EMDN code, but the EMDN field in the ÜTS record was left empty. This was one of the most frequent rejection reasons we met; if the code is in the document, it goes into the record.

  • A higher level EMDN code was entered instead of the detailed terminal term.

  • The GMDN description referred to a single use device while the device was reusable, or the sterile status did not match.

  • The GMDN code in ÜTS differed from the code in the declaration of conformity.

Process

  1. You send the declaration of conformity, any certificate, the device list, the label and the instructions for use.

  2. We extract the codes stated in the documents for each device and ask for the manufacturer's information where a code is missing.

  3. We check every code against the MDR or IVDR and, for Türkiye, against the TİTCK guideline, and list any mismatch with its reason.

  4. We send the code table for your approval.

  5. If we handle your EUDAMED or ÜTS registration, we enter the approved codes and file any request needed to add a missing code.

What you receive

  • A code table per device: EMDN code and term, GMDN code and term, specialty type for Türkiye, the source of each code and the rule it follows.

  • A list of mismatches between documents and devices, with a draft correction request for the manufacturer.

  • Where needed, the text of the ÜTS request to add a code.

  • For bulk registrations, the codes entered in the upload file.

What we need from you

  • The signed, current EU declaration of conformity.

  • The notified body certificate, where one applies.

  • The device list: product name, model or reference number, risk class and Basic UDI-DI.

  • The label and the instructions for use, to check single use and sterile status.

  • Any GMDN or EMDN code information the manufacturer already holds.

Not included

  • Notified body conformity assessment and CE certification.

  • Testing and laboratory work, including choosing or arranging a laboratory.

  • Interpreting or changing your technical specifications.

  • Finding importers or distributors.

Related services

Frequently asked questions

Which nomenclature does EUDAMED use?

MDR Article 26 and IVDR Article 23 require an internationally recognised nomenclature made available by the Commission. That nomenclature is the European Medical Device Nomenclature (EMDN), and its code is a core data element under Annex VI, Part B, point 8.

Does my declaration of conformity need an EMDN code?

Annex IV of the MDR does not list the nomenclature code among the minimum contents of the declaration. In practice, if the code is in the declaration, Türkiye requires the same code in ÜTS, so the code you write in the declaration should be the one you register.

Can a device have more than one GMDN or EMDN code in ÜTS?

No. The TİTCK guideline allows one GMDN code and one EMDN code per device.

What if the code in my declaration looks wrong?

We do not change it. We report the mismatch with the reason, and the manufacturer corrects the declaration.

Do you also cover IVD devices?

Yes. IVDR Article 23 sets the same nomenclature rule, and the TİTCK guideline applies the same code rules to IVDR devices in its Article 30.

Do I need to use you for EUDAMED or ÜTS registration as well?

No. You can take the code table alone and let your own team register. If we handle the registration, we enter the codes ourselves.